Analog/Addressable, Addressable, Conventional and Combination Fire Panels to meet a wide range of applications. From simple sprinkler monitoring to systems including hundreds of points.
The FPA-1000 is recommended for a wide range of commercial and public building applications such as retail, schools, universities, manufacturing plants and health care facilities.
Our analog detectors offer a complete range of options including heat, photoelectric and ionization sensors, CO gas detection, and the innovative Dual Ray Technology - all with the goal of improving detection while minimizing false alarms.
The FCP-500 series is the industry's only flush-mounting ceiling detector. Using revolutionary, patented Bosch technology, the detector appears as a smooth plastic plate, flush with the ceiling surface! There are optional color rings to help further disguise its presence.
Break Glass
Fire Voice Alarm
Fire Voice Alarm
Control panel:
Four initiating zones (expandable to eight); up to 20 two wire smoke detectors per zone
Programmable through keypads or remote programming software (RPS) through a Conettix interface module
Two notification appliance circuits (NACs) on board with a shared internal regulated 24 VFWR, 4 A NAC power supply
Easily converts to addressable with the addition of a D7039 Multiplex Expansion Module
Detector Base:
Connects to multiplex bus of the FPD 7024 or D7024 Addressable FACP, DS7400Xi Control Panel, and G Series Control Panels
Detector's head is easily removed by twisting
Two-piece detector head and base design allows pre wiring the system
Heat Detector:
Mounts on low profile six-inch diameter base
Easy head removal for cleaning and servicing
24 VDC, 190˚F (88˚C) fixed setting
Dual built-in power and alarm LEDs viewable from 360˚
Highly stable operation and RF/Transient protection
Electronic heat sensing operation
Heat Detector:
Mounts on low profile six inch diameter base
Easy head removal for cleaning and servicing
Available in 24 VDC, 135˚F (57˚C) or 190˚F (88˚C) fixed settings
Dual built-in power and alarm LEDs viewable from 360˚
Highly stable operation and RF/Transient protection
Electronic heat sensing operation
Smoke & Smoke heat detector:
Connects to the multiplex bus of the FPD 7024 or D7024 Addressable FACP and the DS7400Xi Control Panel
Superior dust immunity
Exclusive Chamber Check self-diagnostics
Automatic sensitivity test features
Easy disassembly for cleaning
Conventional Heat detector:
Two-wire or four-wire bases
50 ft (15.2 m) maximum spacing between detectors
Visible identification of model: F220 135 = no ring, F220 135F = gray ring,F220 190F = black ring